Clean the nozzle

Your browser does not support the video tag.


Clean the nozzle witch wrench

There are filament residues inside the throat, causing insufficient heating and preventing filament melting, which leads to filament jamming and inability to feed.

1.Unload filament.

2.Press tube fitting on both ends and remove the filament tube.

3.Select “Preheat PETG”, heat the nozzle to 230℃.

4.Use a 1.5mm L-swrench to insert into the nozzle and extrude the remaining filament residue to clear the blockage.

5.Reinsert the tube into the bottom; approximately 6cm deep. Ensure it is fully inserted to avoid future blockages.


Previous Next

PoloPrint Wiki

Table of Contents

Tina2 Serials

  • Introduce
  • Unpacking Guide
  • User Manual
  • Tina2 Plus
  • Wifi Config
  • Wifi Function
  • Calibration
  • Slicing Software
  • Cura
  • Firmware Update
  • Octoprint
  • Maintenance
  • Filament
  • FAQ

Starry Serials

  • Introduce
  • Unpacking Guide
  • User Manual
  • Wifi Config
  • Slicing Software
  • Maintenance
  • FAQ

D120

  • Introduce
  • Unpacking Guide
  • User Manual
  • Wifi Config
  • Wifi Function
  • Calibration
  • Slicing Software
  • Firmware Update
  • Octoprint
  • FAQ

X40 Serials

  • Introduce
  • Unpacking Guide
  • User Manual
  • Dual Extrusion Printing
  • Calibration
  • Wifi Config
  • Wificam Function
  • Slicing Software
  • Firmware Update
  • Octoprint
  • FAQ

ME40 Serials

  • Introduce
  • Unpacking Guide
  • User Manual
  • Calibration
  • Slicing Software
  • Firmware Update
  • FAQ

Links

  • PoloPrint Community
  • Firmware Source Code
  • Slicer Profiles
  • ENTINA official website
  • WEEDO official website
  • WEEFUN official website