Z homing failed
Confirm the issue in the Z direction
Please enter endstop troubleshooting.
1. Check the “endstop“
2.Press the Z endstop manually and observe if the “Off-On” status is displayed correctly.
If it does not display normally, it indicates an issue with the Z direction.
· If it continuously displays “off,” the problem is with the Z endstop.
· If it continuously displays “on,” the issue is with the wire of the Z endstop.
Replace both the Z endstop and the wire
1. Confirm that the shaft coupling shell has been removed, re-insert the plug to see if it works normally.
2. Unplug the Z endstop wire on the motherboard.
3. Cut off the black ties.
4. Use a screwdriver to loosen the screws on the Z endstop and replace it.
If the nozzle does not move, check the Z motor and the mainboard
Move the nozzle to the center, click on “Level bed”, and if the nozzle does not move,this indicates a fault with either the Z motor or the mainboard.
To diagnose the issue:
1. Re-seat the motor wire to see if the issue is resolved.
2. Swap the Y and Z motor wires.
3. Click “Move axis” and jog the Y axis:
①If the nozzle does not rise or fall, but you move the Z-axis and find that the platform moves normally, then you need to replace the Z motor.
②If the nozzle rises or falls, but you move the Z-axis and find that the platform does not move, then you need to replace the mainboard.